نتورک کلینیک - فروش تخصصی تجهیزات شبکه
مشاوره و استعلام قیمت همکاری
N3K-C3064PQ-10GX Specification |
||
| Physical | ● 1RU fixed form factor
● Cisco Nexus 3064-X: 64 10 Gigabit Ethernet ports (48 SFP+ and 4 QSFP+) ◦ ۴۸ SFP ports support 1 and 10 Gigabit Ethernet ◦ ۴ QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each ● ۲ redundant power supplies ● 1fan tray with redundant fans ● ۱ I/O module with management, console, and USB flash memory ports |
|
| Performance | ● ۱.۲۸-Tbps switching capacity
● Forwarding rate of 950 mpps ● Line-rate traffic throughput (both Layer 2 and 3) on all ports ● Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
|
| Hardware tables and scalability | MAC addresses | ۱۲۸,۰۰۰ |
| Number of VLANS | ۴۰۹۶ | |
| Spanning-tree instances | ● Rapid Spanning Tree Protocol (RSTP): 512
● Multiple Spanning Tree (MST) Protocol: 64 |
|
| ACL entries | ● ۲۰۰۰ ingress
● ۱۰۰۰ egress |
|
| Routing table | ● ۱۶,۰۰۰ prefixes and 16,000 host entries
● ۸۰۰۰ multicast routes |
|
| Number of EtherChannels | ۶۴ (with vPC) | |
| Number of ports per EtherChannel | ۳۲ | |
| Buffers | ۹ MB shared | |
| Boot flash memory | ۲ GB | |
| Power | Number of power supplies | ۲
● Cisco Nexus 3064-X: Redundant for AC and DC power |
| Power supply types | ● AC (forward and reversed airflow)
● DC (forward and reversed airflow) |
|
| Typical operating power | ● Cisco Nexus 3064-X
◦ ۱۴۳ watts (W; 64p with Twinax at 100% load; 2 power supply units [PSUs]) ◦ 177W (64p with SR optics at 100% load; 2 PSUs) |
|
| Maximum power | ● Cisco Nexus 3064-X: 199W | |
| AC PSUs
● Input voltage ● Frequency ● Efficiency |
● ۱۰۰ to 240 VAC ● ۵۰ to 60 Hz ● ۸۹ to 91% at 220V |
|
| DC PSUs
● Input voltage ● Maximum current ● Efficiency |
● -۴۰ to -72 VDC ● 33A ● ۸۵ to 88% |
|
| Typical heat dissipation | ● Cisco Nexus 3064-X
◦ ۴۸۸ BTU/hr (64p with Twinax at 100% load; 2 PSUs) ◦ ۶۰۵ BTU/hr (64p with SR optics at 100% load; 2 PSUs) |
|
| Maximum heat dissipation | ● Cisco Nexus 3064-X: 683 BTU/hr | |
| Cooling | Forward and reversed airflow schemes:
● Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports) ● Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies) Single fan tray with redundant fans Hot swappable (must swap within 1 min) |
|
| Sound | Measured sound power (maximum)
● Fan speed: 40% duty cycle ● Fan speed: 60% duty cycle ● Fan speed: 100% duty cycle |
● ۵۹.۷ dBA ● ۶۶.۴ dBA ● ۷۱.۰ dBA |
| Environment | Dimensions (height x width x depth) | ● Cisco Nexus 3064-X: 1.72 x 17.3 x 19.7 in. (4.4 x 43.9 x 50.5 cm) |
| Weight | ● Cisco Nexus 3064-X: 20.5 lb (9.3 kg) | |
| Operating temperature | ۳۲ to 104°F (0 to 40°C) | |
| Storage temperature | -۴۰ to 158°F (-40 to 70°C) | |
| Operating relative humidity | ● ۱۰ to 85% noncondensing
● Up to 5 days at maximum (85%) humidity ● Recommend ASHRAE data center environment |
|
| Storage relative humidity | ۵ to 95% noncondensing | |
| Altitude | ۰ to 10,000 ft (0 to 3000m) | |
دیدگاهها